We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
Tektronix Current Probe
As low as 1 560,00 $
In stock
Tektronix current probe solutions offer:
- The broadest range of AC/DC and AC-only current probes
- Measurement accuracy from uAs to 2000 A
- Best-in-class bandwidth up to 120 MHz
- Best-in-class current clamp sensitivity down to 1 mA
- The only products with 3rd Party Safety Certification (UL, CSA, ETL)
- The only products with bare wire voltage ratings
- Automatic readout and scaling when used with Tektronix oscilloscopes so you don’t have to convert volts to amps or manually set the scaling
Model | Description |
---|---|
A622 | Current Probe: 100 kHz, 10 mA to 100 A, AC/DC, BNC |
A621 | Current Probe: 50 kHz, 10 mA to 2000 A, AC, BNC |
CT2 | CURRENT XMFR; 200MHZ 36A W/PROBE - STATEMENT OF COMPLIANCE WITH THIS PRODUCT |
CT1 | CURRENT XMFR; 1GHZ 12A W/PROBE - STATEMENT OF COMPLIANCE |
CT6 | CT6 PROBE; CURRENT PROBE, HIGH FREQ/SMALL GEOMETRY - CERTIFICATE OF TRACEABLE CALIBRATION STANDARD |
TRCP0300 | Current Probe: 30 MHz, 250 mA to 300 A, AC-Only, BNC Interface |
TCP305A | Probe, AC/DC Current; 50Amp DC, DC-50MHZ, Certificate of Traceable Calibration Standard |
TRCP3000 | Current Probe: 16 MHz, 500 mA to 3000 A, AC-Only, BNC Interface |
TRCP0600 | Current Probe: 30 MHz, 500 mA to 600 A, AC-Only, BNC Interface |
P6021A | Probe, AC Current; 250 Amp AC, 60 MHz, 5 FT w/Term Safety Controlled |
TCP312A | Probe, AC/DC Current; 30 Amp DC, DC-100MHZ, Certificate of Traceable Calibration Standard |
P6022 | Current Probe: 120 MHz, 1 mA to 3 A, AC, BNC |
TCP202A | Probe AC/DC Current; DC coupled 15 Amp Max DC; 50 MHz BW TekProbe Lvl2 Interface; Certificate of Traceable Calibration Standard |
TCPA400 | Current Probe: 50 MHz, Amplifier (Requires Probe) |
TCPA300 | Current Probe: 100 MHz, Amplifier (Requires Probe) |
TCP2020 | CURRENT PROBE; DC COUPLED, 50 MHZ BW, 20 A, BNC interface |
TCP0020 | Probe, AC/DC Current; 20 Amp; 50 MHz BW; TekVPI Interface; Certificate of Traceable Calibration Standard |
TCP303 | PROBE; AC/DC CURRENT; DC-15MHZ,150A DC, CERTIFICATE OF TRACEABLE CALIBRATION STANDARD |
TCP0030A | Probe, AC/DC Current; 30 Amp DC, DC TO 120 MHZ; with TekVPI Interface; Certificate of Traceable Calibration Standard |
TCP404XL | PROBE; AC/DC CURRENT, DC-2MHZ, 500A DC, 750A DC DERATED WITH DUTY CYCLE,CERTIFICATE OF TRACEABLE CALIBRATION STANDARD |
TCP0150 | Current Probe: 20 MHz, 5 mA to 212 A, AC/DC, TekVPI |
SKU
Tektronix Current Probe Family
Manufacturer
Tektronix
Model
Tektronix Current Probe
Bandwidth
DC - 2 GHz
Maximum Current
Up to 300 A
Minimum Current
As low as 200 μA
Rise Time
< 200 ps - < 175 ns
Recommended Accessories
Model | Description |
---|---|
TCP300 and TCP400 Series |
|
TCPA300 Amplifier | AC/DC current probe, DC to 100 MHz, (Requires TCP305A or TCP312A or TCP303 probes) |
TCPA400 Amplifier | AC/DC current probe, DC to 50 MHz, (Requires TCP404XL probe) |
016-1924-00 | Cover, large probe protective; (for TCP303, TCP404XL) |
016-1922-00 | Case, transit; current measurement systems |
011-0049-02 | 50 Ω feedthrough termination |
012-0117-00 | 50 Ω BNC-to-BNC coaxial cable |
012-1605-02 | CABLE ASSY, RF TEKPROBE INTERFACE |
067-2396-00 | Current loop, 1 turn, 50 Ω, BNC connector (for TCP305A, TCP312A, TCP202A) |
015-0601-50 | Current loop, 1 turn, 50 Ω, BNC connector (for TCP303, TCP404XL) |
TCP0020, TCP2020, TCP202A |
|
067-2396-00 | Current loop, 1 turn, 50 Ω with BNC connector used for performance verification |
067-1686-02 | Cal/Deskew fixture for DPO7000/70000 series |
067-1686-03 | Cal/Deskew fixture for DPO7000/70000 series |
A621 and A622 |
|
012-1450-00 | Adapter, lead; discrete – MLD, 2, 18 AWG, dual insul, BNC, female X 4 mm dual insul; banana jack X dual insul plug, shield banana |
P6021A, P6022 |
|
067-2396-00 | Current loop, 1 turn, 50 Ω with BNC connector, used for Performance Verification |
067-1686-02 | Cal/Deskew fixture for DPO7000/70000 series |
067-1686-03 | Cal/Deskew fixture for DPO7000/70000 series |
CT1 · CT2 |
|
011-0049-02 | Feed-through 50 Ω Termination |
TCP0030A |
|
067-2396-00 | Current loop, 1 turn, 50 Ω, BNC connector (for TCP305A, TCP312A, TCP202A) |
TCP0150 |
|
015-0601-50 | Current loop, 1 turn, 50 Ω, BNC connector (for TCP303, TCP404XL) |
067-1701-01 | TekVPI calibration fixture |
067-1686-02 | Cal/Deskew fixture for DPO7000/70000 series |
067-1686-03 | Cal/Deskew fixture for DPO7000/70000 series |
See datasheet for model specific oscilloscope compatibility and standard accessories included. |
Add extended service and calibration
Optimize the lifetime value of your purchase and lower your total cost of ownership with a calibration and extended warranty plan for your instrument.
Plans range from standard warranty extensions covering parts, labor, and 2-day shipping to Total Product Protection with repair or replacement coverage from wear and tear, accidental damage, ESD or EOS. See the table below for specific service options available.
Extended service and calibration options
Service Option | Description | |
---|---|---|
Warranty Extension | ||
R3 | Standard warranty extended to 3 years. Covers parts, labor and 2-day shipping within country. Guarantees faster repair time than without coverage. All repairs include calibration and updates. Hassle free - a single call starts the process. | Contact Testforce Sales Office. |
R5 | Standard warranty extended to 5 years. Covers parts, labor and 2-day shipping within country. Guarantees faster repair time than without coverage. All repairs include calibration andupdates. Hassle free - a single call starts the process. | |
Calibration Coverage | ||
C3 | Option C3: Calibration service 3 years.Includes traceable calibration or functional verification where applicable, for recommended calibrations. Coverage includes the initial calibration plus 2 years calibration coverage. | Contact Testforce Sales Office. |
C5 | Option C5: Calibration service 5 years.Includes traceable calibration or functional verification where applicable, for recommended calibrations. Coverage includes the initial calibration plus 4 years calibration coverage. | |
Data Reports | ||
D1 | Calibration Data Report | Contact Testforce Sales Office. |
D3 | Calibration Data Report 3 Years (with Option C3) | |
D5 | Calibration Data Report 5 Years (with Option C5) |
Contact Us for details